High Voltage (HV) Asynchronous Motors

HIGH VOLTAGE ASYNCHRONOUS MOTORS

DRIP-PROOF HV MOTORS
cooling mode – IC 01


nn


Standards: IEC 60034-1
Rotor type: squirrel cage
Output: 200 – 9.000 kW
Voltage / frequency: 3 – 13.8 kV / 50 Hz, 60 Hz
Frame Size: 355 – 800
Number of poles: 2 – 12
Insulation class: F
Mechanical protection: IP 23
Cooling: IC 01
Mounting arr.: IM B3, IM V1
Fixing dimensions: IEC 60072
Designation: 1.KO(F)

HIGH VOLTAGE MOTORS
cooling mode – IC 611 (air – air)


nn


Standards: IEC 60034-1
Rotor type: squirrel cage
Output: 200 – 8.000 kW
Voltage / frequency: 3 – 13.8 kV / 50 Hz, 60 Hz
Frame Size: 355 – 800
Number of poles: 2 – 12
Insulation class: F
Mechanical protection: IP 54
Cooling: IC 611
Mounting arr.: IM B3, IM V1
Fixing dimensions: IEC 60072
Designation: 1.KZ(F)

HIGH VOLTAGE MOTORS
cooling mode – IC 511 (air – air)


nn


Standards: IEC 60034-1
Rotor type: squirrel cage
Output: 200 – 8.000 kW
Voltage / frequency: 3 – 13.8 kV / 50 Hz, 60 Hz
Frame Size: 355 – 800
Number of poles: 2 – 12
Insulation class: F
Mechanical protection: IP 54
Cooling: IC 511
Mounting arr.: IM B3, IM V1
Fixing dimensions: IEC 60072
Designation: KZ(F)N

HIGH VOLTAGE MOTORS
cooling mode – IC 81 W (air – water)


nn


Standards: IEC 60034-1
Rotor type: squirrel cage
Output: 200 – 9.000 kW
Voltage / frequency: 3 – 13.8 kV / 50 Hz, 60 Hz
Frame Size: 355 – 800
Number of poles: 2 – 12
Insulation class: F
Mechanical protection: IP 54
Cooling: IC 81 W
Mounting arr.: IM B3, IM V1
Fixing dimensions: IEC 60072
Designation: 1.KV(F)

DRIP-PROOF HIGH VOLTAGE WOUND-ROTOR MOTORS
cooling mode – IC 01


nn


Standards: IEC 60034-1
Rotor type: wound-rotor (slip-ring)
Output: 200 – 9.000 kW
Voltage / frequency: 3 – 13.8 kV / 50 Hz, 60 Hz
Frame Size: 355 – 800
Number of poles: 2 – 12
Insulation class: F
Mechanical protection: IP 23
Cooling: IC 01
Mounting arr.: IM B3, IM V1
Fixing dimensions: IEC 60072
Designation: 1.PO(F)

HIGH VOLTAGE WOUND-ROTOR MOTORS
cooling mode – IC 611 (air – air)


nn


Standards: IEC 60034-1
Rotor type: wound-rotor (slip-ring)
Output: 200 – 8.000 kW
Voltage / frequency: 3 – 13.8 kV / 50 Hz, 60 Hz
Frame Size: 355 – 800
Number of poles: 2 – 12
Insulation class: F
Mechanical protection: IP 54
Cooling: IC 611
Mounting arr.: IM B3, IM V1
Fixing dimensions: IEC 60072
Designation: 1.PZ(F)

HIGH VOLTAGE WOUND-ROTOR MOTORS
cooling mode – IC 511 (air – air)


nn


Standards: IEC 60034-1
Rotor type: wound-rotor (slip-ring)
Output: 200 – 8.000 kW
Voltage / frequency: 3 – 13.8 kV / 50 Hz, 60 Hz
Frame Size: 355 – 800
Number of poles: 2 – 12
Insulation class: F
Mechanical protection: IP 54
Cooling: IC 511
Mounting arr.: IM B3, IM V1
Fixing dimensions: IEC 60072
Designation: ZP(F)N

HIGH VOLTAGE WOUND-ROTOR MOTORS
cooling mode – IC 81 W (air – water)


nn


Standards: IEC 60034-1
Rotor type: wound-rotor (slip-ring)
Output: 200 – 9.000 kW
Voltage / frequency: 3 – 13.8 kV / 50 Hz, 60 Hz
Frame Size: 355 – 800
Number of poles: 2 – 12
Insulation class: F
Mechanical protection: IP 54
Cooling: IC 81 W
Mounting arr.: IM B3, IM V1
Fixing dimensions: IEC 60072
Designation: 1.PV(F)

HIGH VOLTAGE MOTORS FOR NUCLEAR POWER PLANTS
cooling mode – IC 611; IC 81 W


nn


Standards: IEC 60034-1
Rotor type: squirrel cage
Output: 200 – 8.000 kW
Voltage / frequency: 3 – 13.8 kV / 50 Hz, 60 Hz
Frame Size: 355 – 1.600
Number of poles: 2 – 26
Insulation class: F / B
Mechanical protection: IP 55
Cooling: IC 411
Mounting arr.: IM B3, B5, V1
Fixing dimensions: IEC 60072
Designation: xxx

FREQUENCY CONTROLLED HIGH VOLTAGE MOTORS
cooling mode – IC 511; IC 516; IC 611; IC 616; IC 666


nn


Standards: IEC 60034-1
Rotor type: squirrel cage
Output: 200 – 4.000 kW
Voltage / frequency: 3 – 6 kV / 50 Hz, 60 Hz
Frame Size: 355 – 800
Number of poles:
Insulation class: F / B
Mechanical protection: IP 55
Cooling: IC 611
Mounting arr.: IM B3, B5, V1
Fixing dimensions: IEC 60072
Designation: xxx

LOW SPEED HIGH VOLTAGE MOTORS
cooling mode – IC 511; IC 516; IC 611; IC 616; IC 666


nn


Standards: IEC 60034-1
Rotor type: squirrel cage
Output: 200 – 8.000 kW
Voltage / frequency: 3 – 13.8 kV / 50 Hz, 60 Hz
Frame Size: 800 – 1.600
Number of poles: 4 – 12
Insulation class: F / B
Mechanical protection: IP 55
Cooling: IC 411
Mounting arr.: IM B3, B5, V1
Fixing dimensions: IEC 60072
Designation: xxx



design ATB SEVER DOO

e-mail webmaster@rs.atb-motors.com